GPR-H500-A-24V
High Voltage DC contactor 500Amps, 1500VDC (DC relay) with AUX-contact. The relay is perfect for applications in automotive, solar, ups, Energy Storage Systems, etc. The magnets take care for the arc blowout. Coil voltage 24VDC.
Share:
Downloads
To get a more deep overview of the total GPR product line, please download one of the pdf’s below: Download Leaflet GPR Relays Download Extended Catalog GPR-SeriesSpecifications (Key features)
Number of poles | 1 pole |
Operating Voltage | up to 1500VDC |
Coil voltage | 24VDC |
AUX contact: | Yes, Normally Open |
Rated impulse withstand voltage, U imp | 8kV |
Conventional thermal Current, Ith | 500 Amps (bi-directional) |
Shorttime withstand current | 2 min: 900 Amps |
Unnamed variable | 15 min: 750 Amps |
Mechanical durability | > 200.000 cycles |
Electrical durability | 200A, 1500VDC, 1.000cycles (at 360 cycles/Hr) |
Voltage drop | 0.04V@20Amps |
Operating time | Max. 35ms |
Release time | Max. 15ms |
Insulation strength (initial) | Min. 100MΩ (@1000VDC) |
Size, W × H × D( mm ) | 118x70x108 |
Temperature range | -40 – 85C |
Humidity | 5-95% R.H. |
Weight | 1300 gr |
Certification | CE, UL |